• 今天是:2025年1月10日 星期五东莞市纵横世纪企业管理咨询有限公司专注于航空航天汽车军工质量培训
  • 网站首页|加入收藏|联系我们
  • TGP风能电力特殊工序

    您当前所在的位置:首页 > 特殊工序 > TGP风能电力特殊工序

    63K
    拉萨市TPG_AC7120认证_AC7120_电路卡组件的审核标准(15)
    发表时间:2021-07-17     阅读次数:     字体:【

    17.1.15.C Is the cleaning method being used as per the procedure and is the maximum time permitted between reflow and cleaning being observed? YES/NO

    Audit Note: Maximum allowed time of 8 hours unless otherwise specified by customer or manufacturer’s recommendation.

    17.2 Wave Soldering N/A

    17.2.1.P Are there procedures that define:

    a.P - Moisture control and/or baking for PB/CCA? YES/NO

    b.P - Moisture control for sensitive components based on J-STD-033 and/or JSTD-020, unless otherwise specified by customer, if used during wave soldering? YES/NO/N/A

    c.P - Flux density measurement of non-water based fluxes, if the density is adjusted? YES/NO/N/A

    d.P - Shelf life control of flux? YES/NO

    e.P - Curing time (if needed) and removal of temporary mask materials, if used? YES/NO/N/A

    f.P - Method of initial program validation, validation of revisions including authorization rules?

    YES/NO

    g.P - Monitoring of controlled atmosphere, if used? YES/NO/N/A

    h.P - Maintenance of air knife nozzles, if used? YES/NO/N/A

    i.P - Setup of equipment, programs and tools including temperatures, speeds, etc.? YES/NO

    j.P - Profile traceability? YES/NO

    k.P - Control and record of solder bath/pot purity (maximum contaminants compliant to J-STD-001)? YES/NO

    l.P - Inspection plan? YES/NO

    m.P - Method of preventing cross contamination of solder alloys and fluxes, if more than one is used? YES/NO/N/A

    n.P - Cleaning method and maximum time permitted between wave and clean for each flux chemistry used? YES/NO

    Audit Note: Maximum allowed time of 8 hours unless otherwise specified by customer or manufacturer’s recommendation.

    Wave Soldering COMPLIANCE

    17.2.1.C Are the PB / CCA being controlled to minimize moisture ingress in accordance with the procedure? YES/NO

    17.2.2.C If used, are moisture sensitive components handled in accordance with the procedure?

    YES/NO/N/A

    17.2.3.C Is the qualified flux and solder alloy being used for the part number being soldered?

    YES/NO

    17.2.4.C If different solder alloys and fluxes are in use, is cross contamination between different solder alloys and different fluxes prevented? YES/NO/N/A

    17.2.5.C Is the flux shelf life being controlled according to the manufacturer’s specification?

    YES/NO

    17.2.6.C If used, is there evidence that the application, curing and removal of temporary mask, is carried out according to the procedure? YES/NO/N/A

    17.2.7.C If adjusted, is the density of non-water based fluxes being controlled as per procedure and manufacturers recommendations? YES/NO/N/A

    17.2.8.C Is set-up of equipment being carried out according to the procedure? YES/NO

    17.2.9.C Is the profile in use being monitored according to the procedure to assure compliance to the defined requirements for temperature and time parameters? YES/NO

    17.2.10.C Is there evidence that the preventive maintenance is complete, including thermocouple calibration, periodic cleaning of equipment and tools and if used air knife nozzle? YES/NO

    17.2.11.C Is the control of solder bath / pot purity monitored in accordance with the procedure?

    YES/NO

    17.2.12.C Are all drawings, machine programs, written instructions, product specific fixtures under configuration control and do they match the assembly traveler? YES/NO

    17.2.13.C Is there evidence of program validation and approval per procedure? YES/NO

    17.2.14.C Is there evidence that the method of program revision is followed? YES/NO

    17.2.15.C Are the work instructions including the sequence of operation being followed? YES/NO

    17.2.16.C Is there evidence the inspection plan is being followed? YES/NO

    17.2.17.C Are soldering defects including solder joint touchup identified, recorded and addressed in a continuous improvement plan? YES/NO

    17.2.18.C If controlled atmosphere is used, is the procedure for monitoring being followed? YES/NO/N/A

    17.2.19.C Is the cleaning method being used as per the procedure and is the maximum time permitted between wave soldering and cleaning being observed? YES/NO

    Audit Note: Maximum allowed time of 8 hours unless otherwise specified by customer or manufacturer’s recommendation.


     