• 今天是:2024年5月19日 星期日东莞市纵横世纪企业管理咨询有限公司专注于航空航天汽车军工质量培训
  • 网站首页|加入收藏|联系我们
  • TGP风能电力特殊工序

    您当前所在的位置:首页 > 特殊工序 > TGP风能电力特殊工序

    63K
    常熟市TPG_AC7120认证_AC7120_电路卡组件的审核标准(12)
    发表时间:2021-07-16     阅读次数:     字体:【

    14.5 Build Through / Build Short N/A

    14.5.1.P Is there a procedure that defines: YES/NO

    a.P - Requirement for manufacturing/process engineering evaluation? YES/NO

    b.P - Method of identification of affected assemblies? YES/NO

    c.P - Details of the missing parts? YES/NO/N/A

    d.P - Protection of unused footprints? YES/NO

    e.P - Definition of the stop points? YES/NO

    f.P - Definition and control of the processes to be used to fit, solder and clean (if required)? YES/NO/N/A

    g.P - Inspection of the fully built assembly? YES/NO

    Build Through / Build Short COMPLIANCE

    14.5.1.C If build through / build short are being performed are they being controlled according to the procedure? YES/NO/N/A

    14.5.2.C If used, are build through / build short assemblies prevented from further processing beyond the defined stop points? YES/NO/N/A

    14.6 Clinched Component Leads N/A

    14.6.1.P Is there a procedure for the clinching process which addresses lead protrusion, minimum electrical clearance requirements, tempered leads and maintenance of the clinch and/or cutter tools? YES/NO

    Clinched Component Leads COMPLIANCE

    14.6.1.C Is the clinching and lead protrusion in accordance with the procedure? YES/NO

    15 IN-PROCESS VERIFICATION / INSPECTION

    15.1 General

    15.1.1.P Are there procedures that define:

    a.P - Overall inspection plan? YES/NO

    b.P - Verification system of part placement that includes a check for missing parts, orientation, polarity and wrong part selection? YES/NO

    General COMPLIANCE

    15.1.1.C Is there evidence that the inspection plan is being followed? YES/NO

    15.1.2.C Are all drawings, machine programs, written instructions, product specific fixtures under configuration control and do they match the Assembly traveler? YES/NO

    15.1.3.C Is the verification system for part placement being followed? YES/NO

    15.1.4.C If the inspection plan states the use of optical magnification tools, are they being used?

    YES/NO/N/A

    15.2 Visual

    15.2.1.P Is there a documented visual inspection plan? YES/NO

    Visual COMPLIANCE

    15.2.1.C Is the procedure for visual inspection being followed? YES/NO

    15.3 AOI N/A

    15.3.1.P Are there procedures that define:

    a.P - Setup and use of AOI? YES/NO

    b.P - Method of initial program validation, and validation of revisions including authorization rules? YES/NO

    c.P - Acceptance of false defects by authorized personnel? YES/NO

    d.P - Prevention of modification of programs by unauthorized personnel? YES/NO

    AOI COMPLIANCE

    15.3.1.C Are the programs used for AOI validated as per the procedure, including any revisions? YES/NO

    15.3.2.C Is the setup of AOI equipment according to procedure? YES/NO

    15.3.3.C Is the acceptance of false defects only carried out by authorized personnel per procedure? YES/NO

    15.4 X-Ray N/A

    15.4.1.P Are there procedures that define:

    a.P - For the X-Ray program to be validated, if programmable inspection equipment is used?

    YES/NO/N/A

    b.P - X-ray training? YES/NO

    c.P - Setup of X-Ray equipment? YES/NO

    d.P - Method of initial program validation and validation of revisions including authorization rules, if programmable inspection equipment is used? YES/NO/N/A

    e.P - Acceptance of false defects by authorized personnel, if programmable inspection is used?

    YES/NO/N/A

    X-Ray COMPLIANCE

    15.4.1.C If programmable X-Ray is used, are the programs validated as per the procedure, including any revisions? YES/NO/N/A

    15.4.2.C Is there evidence of X-Ray training? YES/NO

    15.4.3.C Is the setup of X-Ray equipment according to procedure? YES/NO

    15.4.4.C If programmable inspection is used, is the acceptance of false defects only carried out by authorized personnel per procedure? YES/NO/N/A

    15.4.5.C If programmable inspection is used, are the staff who generate the X-Ray programs trained to perform this activity? YES/NO/N/A


     
    上一篇:南京市TPG_AC7120认证_AC7120_电路卡组件的审核标准(11)
    下一篇:无锡市TPG_AC7120认证_AC7120_电路卡组件的审核标准(13)